Compare Low E Coatings (Samples of Low E Coatings)
Visible Light Transmittance % ▼ |
Solar Heat Gain Coefficient ▼ |
UV % ▼ |
|
---|---|---|---|
CARDINAL | |||
LoĒ²-270 (6mm) | 68% | 0.35 | 0.13 |
LoĒ³-366 (6mm) | 63% | 0.27 | 0.04 |
LoĒ²-270, LoE-i89 | 69% | 0.36 | 0.14 |
LoĒ³-366, LoE-i89 | 63% | 0.27 | 0.05 |
PPG | |||
Solarban 60 | 70% | 0.38 | 0.19 |
Solarban 70XL | 64% | 0.27 | 0.06 |
Sungate 500 | 74% | 0.62 | 0.42 |
GUARDIAN | |||
SunGuard SN 68 | 68% | 0.38 | 0.29 |
SunGuard SNX 62/2 | 62% | 0.27 | 0.06 |
SunGuard SNR 43 | 43% | 0.23 | 0.17 |
SunGuard Neutral 78/65 | 78% | 0.65/0.62 (#3/2) | 0.38 |
Visible Light Transmittance % ▼ |
Solar Heat Gain Coefficient ▼ |
UV % ▼ |
Fade Transmittance ▼ |
|
---|---|---|---|---|
LoĒ²-270 | 68% | 0.35 | 0.13 | 0.50 |
Solarban 60 | 70% | 0.38 | 0.19 | 0.56 |
Comparison Reference for Cardinal LoĒ³-366 and PPG Solarban 70XL | ||||
LoĒ³-366 | 63% | 0.27 | 0.04 | 0.41 |
Solarban 70XL | 64% | 0.27 | 0.06 | –– |
Comparison Reference for Cardinal LoĒ²-270 / LoĒ-i89, LoE³-366 / LoĒ-i89 and PPG Solarban 60/Sungate 500 |
||||
LoĒ²-270, LoĒ-i89 | 69% | 0.36 | 0.14 | 0.51 |
LoĒ³-366, LoĒ-i89 | 63% | 0.27 | 0.05 | 0.41 |
Solarban 60/Sungate 500 | 65% | 0.36 | 0.15 | –– |
Visible Light Transmittance % ▼ |
Solar Heat Gain Coefficient ▼ |
UV % ▼ |
Ideal Climate ▼ |
|
---|---|---|---|---|
Comparison Reference for SunGuard SuperNeutral 68 and PPG Solarban 60 | ||||
SunGuard SN 68 | 68% | 0.35 | 0.29 | * |
Solarban 60 | 70% | 0.38 | 0.19 | All |
Comparison Reference for SunGuard 62/27 and PPG Solarban 70XL | ||||
SunGuard SNX 62/27 | 62% | 0.27 | 0.06 | * |
Solarban 70XL | 64% | 0.27 | 0.06 | All |
Comparison Reference for SunGuard SNR 43 and PPG Solarban R100 | ||||
SunGuard SNR 43 | 43% | 0.23 | 0.17 | * |
Solarban R100 | 42% | 0.23 | 0.12 | All |